The procedure for installing electrical wiring in the bathroom with your own hands


Vladimir Sadovsky

Today it is difficult to imagine a bathroom without lamps, sockets, automatic ventilation systems and other equipment that consumes electricity (boilers, washing machines, etc.). And just a few decades ago, the overall load on electrical wiring in such rooms was minimal.

However, the installation of electrical wiring in the bathroom is specific for a number of other reasons. For example, conditions of high humidity prevail in the room. Therefore, in this case, safety precautions, norms and rules must be followed verbatim and carefully.

Bathroom wiring requirements

To ensure safe wiring in the bathroom, follow a few rules:

  • the wire should be laid perpendicular to the walls, floor and ceiling - vertically or horizontally (this will simplify the search for the desired area in the event of a break);
  • the cable should be hidden in high-quality corrugation;
  • the socket and switch must be located at a height of 900 mm from the floor (above a bathtub, sink or water supply - at a height of no less than 700 mm);
  • the presence of separate wiring for each device or power supply point;
  • protection class of the equipment used is not lower than IP44;
  • no twists or connections of multiple wires (only one-piece cable for each wiring);
  • The installation of distribution boxes is strictly prohibited;
  • functional grounding required.


Basic requirements for electrical wiring in the bathroom

How to make grounding

An important element of safety is grounding, which is especially important in the bathroom due to the high humidity of the room. Currently, a 3-core cable is used, where in addition to the phase and neutral wires, a third wire is for grounding.

In older houses with two-core cable wiring, grounding was done by running the ground cable to a distribution panel that has a ground connection.

It also happens that in older houses the distribution panel does not have its own grounding; in such cases, the ground wire is connected directly to the housing. With this method, it is necessary to do the wiring through the RCD device, otherwise the device will burn out.

Drawing up a plan and electrical circuit diagram

Before you begin installing electrical wiring in the bathroom, you need to draw up and outline a work plan. Decide where the main objects will be located - a bathtub or shower stall, a sink, and so on. Having done this, you can decide at which points large household appliances will fit (if they are in the bathroom): a washing machine and/or a boiler.

Then you need to figure out the lighting of the room. The main lighting fixture can be installed on the ceiling or wall. Additional lamps are usually placed above the sink. The next step is to calculate the required number of sockets and switches. You cannot go overboard with such electrical elements: there should be a minimum of them, but enough to power the main devices. In addition, remember to protect against dust and moisture.


Wiring diagram for electrical equipment in the bathroom

Once you have a detailed plan for the location of large objects, household appliances and electrical points, you can begin to draw up a wiring diagram in the room. You need to calculate the total power consumed by all electrical appliances in the bathroom. If possible, move one or two outlets and switches outside the bathroom. You can install them near the entrance. The distribution box should be organized exclusively outside the premises. For each household appliance, a separate automatic switch should be allocated.

Laying cables and sockets

First, it is necessary to determine with maximum accuracy the locations of electrical points, then mark with lines on the walls the routes for laying the cable, the principle of vertical - horizontal laying is observed.

The cable should be laid behind the decorative finish of the bathroom. The groove and the size of the groove must take into account the size of the corrugated sleeve.

After the cable is laid, it is covered with gypsum/alabaster mortar.

Next, the socket boxes are installed so that they extend to their full depth and their edge coincides with the surface of the front finish. They are also fastened with alabaster mortar.

Tools and necessary materials

To install electrical wiring in the bathroom, you will need:

  • wall chaser or drill (as a last resort - hammer drill);
  • Screwdriver Set;
  • screwdriver with indicator;
  • tape measure from 5 m;
  • building level;
  • pliers;
  • hammer and chisel;
  • insulating tape;
  • stationery knife.

A hammer and chisel are used in rare cases when, due to cramped conditions, it is not possible to make grooves using specialized equipment or a hammer drill.


Wiring Tools

Pay attention to the selection of materials. You need to choose high-quality products from trusted manufacturers that meet a given level of protection: waterproof sockets, triple-insulated copper cable with a certain cross-section depending on the power consumption. Carefully inspect the wiring before and after installation to ensure there are no severe bends or cracks in the insulation.

INSTALLATION WORK

In accordance with the developed diagram, the location of electrical fittings and cable routing are marked. Depending on the wall material and the intended finishing method, the cable fastening method is selected:

Tiles on plaster.

On brick walls, grooves are made; on walls made of reinforced concrete, it is possible to secure the cable using special clamps with dowels on the surface of the base.

Tiles on gypsum plasterboard or PVC panels on lathing.

The cables are located in a plastic corrugation, which is attached to the surface of the walls using clamps. The corrugation should be filled to no more than 40% of its volume.

It is recommended to use specialized plastic clamps that are not subject to corrosion and are resistant to thermal expansion of the cable.

It is advisable to select grooves in the walls with a special tool - a wall cutter, but most often a grinder and a hammer drill are used, which is less productive and threatens serious damage to building structures. Places for socket boxes are drilled out with a special drill - a crown with a diamond cutting edge, 68 mm in diameter.

After installing the socket boxes, they are secured in place using special spacer screws, but experienced craftsmen additionally fasten them to alabaster or cement mortar.

The wiring in the grooves is fixed every 20 cm. For this, it is recommended to use special dowel clamps, but most electricians grab the wires with a small amount of solution.

The ends of the wires are stripped and inserted into the technological hole of the socket box. Before plastering the walls, it is advisable to use a multimeter to check the integrity of the wire by its resistance and the presence of a short circuit on the line.

The cores of sockets and switches are installed and connected. It is better to install the cover and decorative overlays after the completion of the repair or at least the completion of the plastering work.

An RCD and a circuit breaker are installed in the electrical distribution panel. If necessary, a transformer is mounted there if the lighting in the bathroom is based on 12V.

Installation instructions

Below is a step-by-step installation of electrical wiring in the bathroom.

Removing old wiring

New electrical wiring may be required in two cases: the apartment was put into operation without communications or the old wiring in the residential premises no longer satisfies electrical and fire safety. Every year the load capacity of household appliances increases. What was relevant 10 years ago today seems absolutely unsafe and inappropriate, and can lead to overheating and fires.


Replacing electrical wiring in the bathroom

The advisability of replacing the wiring can be judged by how often the machines are knocked out. Also, new electrical wiring is necessary when combining a bathroom and toilet. At a minimum, you need to study the old lines.

Dividing space into zones

The list below is the zonal division of the bathroom (WC) into areas according to the criterion of “electrical danger” (from most to least dangerous):

  1. Zone 0. Bathroom and shower - the area of ​​maximum risk.
  2. Zone No. 1. Imaginary walls located along the edges of the bathtub or shower tray. The threat level is slightly less than in the zero zone.
  3. Zone No. 2. A buffer area 60 cm wide from the edges of zone No. 1.
  4. Zone No. 3. The rest of the area is from zone No. 2, up to 240 cm wide. The place is considered the safest.


An example of zoning space in a bathroom
Mark the bathroom in accordance with the zonal division above. Each individual zone has its own electrical safety requirements:

  1. In the “zero” zone, devices and materials with the highest degree of protection from moisture are required (IP*7, the first digit is protection from dust). It is strongly recommended to use devices (for example, an additional light may be needed) with voltages up to 12 V. The 220 V power source should be located outside the area. Make sure there is no galvanic connection.
  2. In the first zone, it is enough to install devices with IP*5 moisture protection. In this area you can place equipment for heating water. It is enough to ensure that the protection class complies with the specified standard. In this case, the operation of the devices will be safe.
  3. In the second zone, IP*4 class products will be required. In terms of protection, they are practically no different from the previous ones.
  4. In the third zone, a minimum protection of IP*1 is acceptable, since the likelihood of splashes and drops is minimal. Sockets can be installed in these areas.


Degree of protection of luminaires depending on the zone

Laying cables and sockets

When drawing up a plan, you must decide where the sockets, switches and lamps will be located, and only then draw up a wiring diagram. Cable installation may be affected by certain conditions where there is or is no void in the wall and ceiling, or where walls without panels are used.

If there is a void, then you can hide corrugated pipes with cable inside it. It is attached along the profile using pre-drilled holes. It is located strictly vertically. If there is no void, you will have to make grooves. The corrugation with the cable is laid in them, and grooves are used for fastening. In the third case, when using walls without panels, large grooves will be needed to accommodate corrugated pipes. After placing the electrical wiring, the grooves are covered with alabaster, and after leveling the walls, they are hidden under the tiles.


In the bathroom, the cable is laid in corrugated grooves

When the wiring is ready, the socket boxes are installed. Alabaster is used to fix these devices. Sockets with grounding protection should be installed. You need to run a three-core cable to them.

Wire cross-section

Manufacturers of electrical appliances for the bathroom try to produce equipment with minimal power consumption, so small cross-section wires can be used.

Rosette lines

Each point or device must have separate wiring. A total load of up to 3.5 kW is allowed per outlet. This value corresponds to copper wires with a cross-section of 2.5 square meters. mm. It is not advisable to use a cable with a larger cross-section in the bathroom. It costs more, but does not carry any semantic meaning (you still do not have the right to connect several household appliances to the outlet through a tee).

The only option is when the wire cross-section can be increased to 4 square meters. mm - electrical wiring using cable type PUGNP or analogues of the ShVVP version. This wire is produced not according to GOST, but according to technical specifications. Therefore, often the cross-section declared by manufacturers may not correspond to the real one, which means you have to take a reserve. A similar situation is observed with the VVGng wire. Ideally, you need to buy products manufactured in accordance with GOST.


Electrical wire PUGNP 3*1.5

Lighting lines

The lighting line can be powered using a wire with a cross-section of 0.75-1.5 square meters. mm. In this case, each line segment must have the same characteristics. It is impossible to draw the main line from the junction box using a cable of one section, and then feed wires of a different section to the lighting fixtures. This will lead to incorrect functioning of the circuit breaker: a device designed for large-section wires simply will not work with a cable of a smaller diameter. Lack of protection will lead to overheating.

The purpose of the circuit breaker is to protect electrical wiring from overloads and fire. It does not affect the operation of household appliances. Thus, the power of the machine is selected depending on the cross-section of the cable being laid. For a wire of 1.5 sq. mm, a machine with a nominal value of 10 A, 2.5 sq. mm is suitable. mm - 16 A.

A similar method is used when connecting electrical equipment in the bathroom from a common line. Focus on the highest consumers, which include sockets. If the sockets are connected with a 2.5 sq.m. cable. mm, then all other wires on the line (including those connected to lighting devices) must have an identical cross-section.


Wiring in the bathroom on the ceiling for lamps

If a hopeless situation arises and you need to switch from a larger cross-section to a smaller one, then an additional machine of the required rating (corresponding to a cable of a smaller cross-section) must be installed at the transition point. For lighting, a machine with a nominal value of 6 A is usually used, and sockets - 10 A. But in a bathroom this is difficult to implement: installing an additional machine is a labor-intensive process, so it is recommended to avoid it.

Ceiling lights

A bathroom with a suspended ceiling should be equipped with ceiling lighting devices. They will be much easier to connect to a common network cable, and this type of lighting is generally considered more efficient and attractive.


In the bathroom it is preferable to use ceiling lamps

A modern ceiling lamp is a multifunctional device that, among other things, can have an adjustable lighting angle. But even with this layout, the cable should be hidden in a corrugated sleeve, and terminals should be used to fix it to the ceiling.

Safety sockets

For sockets, an additional RCD with a rated current corresponding to the machine (or slightly higher) is required. If the difference in rated voltage is excessive, the equipment will not operate correctly. For modern washing machines, 16 A sockets are suitable, which are equipped with a ceramic surface to protect them from splashes.


Waterproof sockets for wet areas

RCD, difavtomat and grounding

The bathroom must meet the highest electrical safety requirements. The likelihood of death from electric shock is high, so lines with sockets should be protected by an RCD. To ensure correct operation of this device, you must use a grounding loop connected to the corresponding cell of the distribution panel.

There are no problems with this in modern residential buildings. In high-rise buildings, wiring with N and PE conductors is pre-installed, which makes it easy to connect to the ground loop. But the bathroom requires a potential equalization bar. The design of this element is a simple metal plate to which several contacts are attached. Such a bar can be created manually. The most primitive option is to weld M6 bolts onto a piece of plate and screw nuts on them. The grounding conductors of every metal object installed in the bathroom, including the bathroom itself, must be connected to it. One exception would be an electric dryer, where the outside of the dryer is automatically connected to ground via the power cord.


Grounding appliances in the bathroom

The situation is much worse with grounding loops in old apartment buildings (for example, Khrushchev buildings). Instead of grounding according to former electrical safety standards, grounding was used. The neutral and grounding circuits were combined into one. There is simply no grounding in the distribution panels at the entrance to the house. Without carrying out major repairs to the entrance, it will not be possible to do such work with your own hands. This will be especially difficult if the apartment is on the third floor or higher.

In such situations, if you do not want to spend a lot of money on grounding the entrance, you will have to replace the RCD with a difavtomat. It is triggered instantly as soon as it detects the appearance of a leakage current. But unlike an RCD, it does not require a ground loop to operate. The disadvantage of the difavtomat is that it is a less sensitive and more “rough” device for protecting the electrical line. But in most cases, such a replacement is completely justified, and often it is the only alternative option.


Connecting a washing machine

It is difficult to select the rating of the RCD. To carry out correct calculations, you need knowledge of the basics of electrical engineering and a clear understanding of the principles of operation of modular machines.

It is important to remember the following:

  1. There are several types of RCDs. The main classification is the rated value of the leakage current for the device to operate.
  2. Household electrical appliances and exposed wiring in the house are protected by AB (more expensive) and AC circuit breakers (available, but may not operate correctly if a device with switching power is connected to the line).
  3. RCDs are triggered by a certain amount of differential current. For the bathroom, devices rated at 10 mA are suitable.

A residual current device, unlike a circuit breaker, cannot de-energize the entire line. However, each device can operate at a certain amount of current, providing the line with the electrical parameters of the desired value. In this mode, the RCD can function for a long time. The maximum current value for the RCD must be identical or greater than the sum of the ratings for all machines on a given line.

To determine the rated current of the RCD, the following sequence is used:

  1. If the total power of all electrical devices connected to the same line does not exceed 3.5 kW, then a device with a rating of 10 mA is suitable.
  2. If the power is higher than 3.5 kW, then you should connect equipment at 30 mA (the fact is that there are no RCDs designed for any currents between 10 and 30 mA).

But this is a “double-edged sword”: an RCD rated at 30 mA itself is a risk of electric shock, so try to get by with the minimum value. The same principle should be used when replacing RCDs with difavtomats and choosing their nominal value.

Marking the degree of protection of electrical appliances

The world uses the marking of the degree of protection of electrical devices, which is designated: International Protection - IP. The degree of protection itself is read by two numbers that come after the letters.

Number indicating protection against exposure to solid particles (first after the letter designation)Number indicating protection against moisture (second after letters)
IPDecoding the numbersIPDecoding the numbers
1Protection against solid bodies larger than 5 cm. Dangerous parts are hidden from touching the back of the hand.1From drops of liquid falling vertically.
2Protection from solid bodies larger than 1.2 cm. No contact of dangerous parts with fingers.2From drops that fall at an angle of 15° to the vertical axis.
3From solid objects measuring 0.25 cm. It is impossible to touch dangerous parts with the tool.3The drop angle is 60°. Protection from them.
4Protection against contact with dangerous parts by wire or against hard parts measuring 1 mm.4Drops fall on the device from all sides and the degree of protection against this phenomenon.
5From dust particles that can stop or damage the electrical appliance.5Protection against a jet of liquid that hits the device from any angle.
6Complete protection against small particles.6The device is protected from drops and jets under pressure.
No protection7From a short immersion in water of 15 cm and up to 1 m.
8The manufacturer indicates the time for protecting the device from exposure to water when it is immersed for a long time to a depth of more than 1 m.
No protection

Precautionary measures

When installing, operating and maintaining electrical wiring in the bathroom, the same precautions apply:

  1. The room should be completely de-energized.
  2. Only use tools that are in good working order and are protected against electric shock.
  3. Use protective equipment, including construction gloves and goggles.


Protective equipment for electrical installation work
Any work related to changing electrical wiring must be carried out by qualified personnel. It is highly undesirable to get involved in this process on your own without the necessary knowledge and work experience.
Especially in the bathroom, where even the slightest mistake can lead to tragic consequences.